Visit ComfyUI Online for ready-to-use ComfyUI environment
Facilitates integration of integer OSC messages for real-time project control.
The VrchIntOSCControlNode
is designed to facilitate the integration of Open Sound Control (OSC) messages into your creative projects, specifically focusing on integer data types. This node acts as a bridge between OSC messages and your application, allowing you to receive, process, and utilize integer values transmitted over a network. By leveraging this node, you can dynamically control various aspects of your project in real-time, such as adjusting parameters or triggering events based on incoming OSC data. The node ensures that the received integer values are appropriately remapped and clamped within specified ranges, providing a robust and flexible solution for interactive and responsive applications. Its primary goal is to enhance your creative workflow by enabling seamless communication between different software and hardware components using the OSC protocol.
The server_ip
parameter specifies the IP address of the OSC server that the node will connect to. This is crucial for establishing a network connection to receive OSC messages. The correct IP address ensures that the node can communicate with the intended server, allowing it to process incoming data effectively. There are no specific minimum or maximum values for this parameter, but it should be a valid IP address format.
The port
parameter defines the network port on which the OSC server is listening for incoming messages. It is essential for directing the OSC messages to the correct application or service. The port number must be within the valid range of 0 to 65535, with a default value typically set by the application or user preference.
The path
parameter indicates the OSC address pattern that the node will listen to. This pattern helps filter and identify specific messages intended for this node, ensuring that only relevant data is processed. The path should be a valid OSC address string, and its format is crucial for the correct operation of the node.
The input_min
parameter sets the minimum expected value for incoming integer data. This value is used to remap the input range to the desired output range, ensuring that the data is processed correctly. The parameter must be less than or equal to input_max
, and its default value is typically determined by the application's requirements.
The input_max
parameter defines the maximum expected value for incoming integer data. It works in conjunction with input_min
to remap the input range to the output range. The parameter must be greater than or equal to input_min
, and its default value is usually set based on the application's needs.
The output_min
parameter specifies the minimum value for the remapped output data. This value is crucial for scaling the input data to the desired output range. The parameter must be less than or equal to output_max
, and its default value is typically determined by the application's requirements.
The output_max
parameter sets the maximum value for the remapped output data. It works with output_min
to define the output range for the processed data. The parameter must be greater than or equal to output_min
, and its default value is usually set based on the application's needs.
The output_invert
parameter is a boolean that determines whether the output range should be inverted. If set to true, the remapped output values will be inverted, providing flexibility in how the data is utilized. This parameter does not have a minimum or maximum value, as it is a simple true or false setting.
The debug
parameter is a boolean that enables or disables debug mode. When enabled, the node will print additional information about its operations, which can be helpful for troubleshooting and understanding the node's behavior. This parameter does not have a minimum or maximum value, as it is a simple true or false setting.
The int_value
output parameter represents the processed integer value received from the OSC message. This value is remapped and clamped according to the specified input and output ranges, ensuring that it fits within the desired limits. The int_value
is crucial for driving various aspects of your project, such as controlling parameters or triggering events based on the received data.
server_ip
and port
parameters are correctly set to match the OSC server you intend to connect to, as incorrect settings will prevent the node from receiving messages.debug
parameter to troubleshoot and verify the node's operations, especially during the initial setup or when encountering unexpected behavior.input_min
, input_max
, output_min
, and output_max
parameters to ensure that the remapped values align with your project's requirements, providing the desired control and responsiveness.output_min
parameter is set to a value greater than output_max
, which is not allowed as it would result in an invalid output range.output_min
is less than or equal to output_max
to define a valid output range.input_min
parameter is set to a value greater than input_max
, leading to an invalid input range.input_min
parameter to be less than or equal to input_max
to establish a valid input range.server_ip
, port
, or debug
) have been altered, requiring the node to update its connection settings.© Copyright 2024 RunComfy. All Rights Reserved.