Visit ComfyUI Online for ready-to-use ComfyUI environment
Facilitates dynamic selection between two conditioning inputs based on a specified value for AI art generation.
The SeargeConditioningMuxer2
node is designed to facilitate the selection between two conditioning inputs based on a specified selector value. This node is particularly useful in scenarios where you need to dynamically switch between different conditioning data streams during the execution of your AI art generation process. By providing a simple yet effective mechanism to choose between two inputs, it helps streamline workflows and ensures that the appropriate conditioning data is used at the right time, enhancing the flexibility and control over the conditioning process.
This parameter represents the first conditioning input. It is one of the two possible conditioning data streams that the node can select from. The type of this input is CONDITIONING
, which means it should be a valid conditioning data object used in your AI art generation process.
This parameter represents the second conditioning input. Similar to input0
, it is a conditioning data stream that the node can select from. The type of this input is also CONDITIONING
, ensuring consistency in the type of data being processed.
This parameter is an integer that determines which of the two conditioning inputs (input0
or input1
) will be selected as the output. The input_selector
can take values of either 0 or 1, with 0 being the default value. If the input_selector
is set to 0, input0
will be selected; if set to 1, input1
will be selected. This parameter allows for dynamic switching between the two inputs based on the needs of your workflow.
The output parameter is the selected conditioning input based on the value of the input_selector
. The type of this output is CONDITIONING
, which means it will be a valid conditioning data object that can be used in subsequent nodes or processes in your AI art generation workflow. The output ensures that the appropriate conditioning data is passed forward, maintaining the integrity and flow of your conditioning data.
input_selector
parameter to dynamically switch between different conditioning inputs during runtime, allowing for more flexible and adaptive workflows.input0
and input1
are valid conditioning data objects to avoid any inconsistencies or errors in the output.input0
or input1
) are not valid conditioning data objects.input0
and input1
are correctly formatted and valid conditioning data objects before passing them to the node.input_selector
parameter is set to a value outside the allowed range (0 or 1).input_selector
is set to either 0 or 1 to correctly select between the two conditioning inputs.© Copyright 2024 RunComfy. All Rights Reserved.